Critical AngleCalculatorsMagnetometry

Magnetometry and UXO

How anomalies scale with distance and mass, what a survey can detect and how far its sensors reach, depth and burial estimates, and the processing checks: sampling, lag and diurnal.

8 calculators · Quick checks with published formulas, not a replacement for your project’s procedures, specifications or acquisition software. Everything runs in your browser: nothing you type is sent anywhere.

3.1

Anomaly fall-off with distance

#

How an anomaly changes with the distance between sensor and source. The exponent depends on the shape of the source: its structural index.

ΔT2 = ΔT1 (r1r2)N

Source
nT
m
m
ΔT2 Anomaly at the new distance–nT
Change
–
Same reading, other shapes
–

Notes and sources

N is 3 for a compact object such as ordnance, an anchor or a barrel, 2 for a pipe or cable, 1 for a dyke or sill and 0 for a contact. Example: 20 nT measured 4 m from a compact object becomes 5.9 nT at 6 m; from a cable it would still be 8.9 nT.

Sources: Breiner, Applications Manual for Portable Magnetometers, Seequent Oasis montaj: located Euler deconvolution

3.2

Mass, anomaly and distance

#

A first estimate of the anomaly an iron mass gives at a distance, or of the mass behind an anomaly, through a constant k.

ΔT = kmr3, m = ΔT r3k

ksphere ≈ 3B02πρ ≈ 3.0 nT·m³/kg

Work out
Examples
nT
m
ΔT Anomaly–nT
Ferrous mass–kg
With k from 3 to 10
–
In pounds
–lb

Notes and sources

k turns mass into anomaly, and published values differ more than tenfold, so the band from k = 3 to 10 comes with every answer. 3.0 is a highly permeable steel sphere in a 50 000 nT field, from Breiner’s dipole; 3.8 a modelled 500 lb bomb in its worst orientation (Underhay et al.); 4.1 the CENOS specification’s 126 kg item; 5.4 the OWA example; 10 Hall (1966), the single value CISMAS recommends; Geometrics’ table implies 34–68. Example: 126 kg at 8 m gives 0.7 nT with k = 3, 1.0 nT with k = 4 and 2.5 nT with k = 10. CISMAS found mass estimates can be out by a factor of 10 and depths by 2: to set thresholds, model the project’s own items in its own field.

Sources: CISMAS: marine magnetometers theory study, Underhay et al. (2024), Hydrographische Nachrichten 128, CENOS UXO survey specification, Carbon Trust OWA guidance, Geometrics G-882, Breiner, Applications Manual for Portable Magnetometers

3.3

Detection distance and smallest detectable mass

#

Turns a noise floor into a detection capability: the furthest a given item can be seen, or the smallest item seen at a given distance.

ΔTmin = SNR × noise, rdet = (kmΔTmin)1/3, mmin = ΔTmin r3k

Work out
Examples
nT
m
rdet Detection distance–m
mmin Smallest detectable mass–kg
ΔTmin Picking threshold, SNR × noise
–nT
With k from 3 to 10
–
In pounds
–lb

Notes and sources

A detection needs the anomaly to clear the noise by a margin: an SNR of at least 3 (OWA); 3H Consulting puts the smallest detectable anomaly at 2–3 times the noise floor, and Underhay et al. use a 3 nT picking threshold. Example: a 500 lb (226.8 kg) bomb against a 3 nT threshold is detectable to 6.6 m with k = 3.8, or 9.1 m with k = 10. At 5 m, with a 5 nT threshold and k = 10, the smallest detectable mass is 62.5 kg (CISMAS’s table: 63 kg). The distance runs from the sensor to the item, so altitude and burial both count: 3.4 turns it into a line spacing.

Sources: Carbon Trust OWA guidance, 3H Consulting: Marine Magnetometer Processing, Underhay et al. (2024), Hydrographische Nachrichten 128, CISMAS: marine magnetometers theory study

3.4

Sensor reach, line spacing and highest altitude

#

How far to either side a sensor still detects the design item at the design burial, and from that the line or array spacing, or the highest altitude that still works.

rc = rdet2 − (a + b)2, Ssingle ≤ 2rc

Warray = (n − 1)s + 2rc, amax = rdet2 − (S/2)2 − b

Examples
m
m
m
m
m
rc Reach to each side, at the burial depth–m
Warray Swath covered by one pass
–m
Inside the array
–
Line spacing
–
amax Highest altitude for that line spacing
–m

Notes and sources

rdet comes from 3.3, for the design item and the picking threshold. A sensor detects the item anywhere inside a sphere of that radius; at the burial depth the sphere cuts a strip 2rc wide. Example on the CENOS basis (rdet = 8 m for 126 kg, 2 m of burial): at 6 m altitude the reach is zero, which is why 6 m is that specification’s ceiling; at 4 m it is 5.3 m, so lines up to 10.6 m apart; at 3 m it is 6.2 m, and four sensors 1 m apart cover 15.5 m. For lines 10 m apart the altitude must stay at or below 4.2 m. To characterise anomalies rather than only detect them, the OWA guidance asks for about 3 lines per anomaly half-width, or 5 for modelling. Altitude limits: below 4 m where ordnance is suspected (BSH); 3–5 m typical (OWA); 6.0 m at most (CENOS).

Sources: CENOS UXO survey specification, Carbon Trust OWA guidance, BSH Standard Ground Investigations, Table 6

3.5

Distance and burial from the half-width

#

A quick distance to the source from the anomaly’s shape on a profile, then the burial from the sensor’s altitude.

z ≈ 2x½ dipole or pipe, z ≈ 1.3x½ monopole, z ≈ x½ dyke edge

b = z − a

Source
Width measured
m
m
z Distance to the source–m
b Burial below the seabed
–m
Full width at half maximum
–m
Half-width
–m

Notes and sources

x½ is the horizontal distance from the peak to where the anomaly falls to half the peak, so for a dipole the full width at half maximum roughly equals the distance. Breiner’s rules assume a vertical field and usually give maximum estimates, often within 10% and sometimes 50% out. At the North Sea’s inclination of about 66° a point dipole still gives a full width at half maximum close to its depth. Example: an anomaly that halves 2.5 m from its peak puts the source about 5.0 m below the sensor; at 3.0 m altitude that is about 2.0 m of burial.

Sources: Breiner, Applications Manual for Portable Magnetometers, Carbon Trust OWA guidance, Underhay et al. (2024), Hydrographische Nachrichten 128

3.7

Sample spacing and sampling adequacy

#

Whether along-track sampling is dense enough to define the anomaly of a source at a given distance.

Δx = vfs, Δx < d2 (ideally d/3 to d/5)

Examples
Hz
m
Δx Sample spacing–m
Needed: under d/2
–m
Ideal: d/5 to d/3
–m
Samples across the anomaly (about d wide)
–
Sampling
–

Notes and sources

d is the smallest source-to-sensor distance you expect: altitude plus burial. An anomaly is about as wide as that distance, so samples closer than d/2 define it, and d/3 to d/5 define it well. Example: 4.5 kn at 10 Hz samples every 0.23 m, and an Overhauser sensor at 4 Hz every 0.58 m; for d = 3 m the ideal is 0.6–1.0 m, so both pass. CENOS asks for at least 10 Hz; caesium sensors in marine work run at 10 Hz or less, since higher rates add noise (3H Consulting).

Sources: Underhay et al. (2024), Hydrographische Nachrichten 128, CENOS UXO survey specification, 3H Consulting: Marine Magnetometer Processing

3.8

Layback and lag

#

The shift that puts readings at the sensor rather than the antenna, and the timing lag that shows when one target appears split on reciprocal lines.

n = Lv fs, Δtlag = dsep2v

Examples
m
Hz
m
Layback as a time shift–s
Δtlag Timing lag–s
n Layback shift in samples
–
Lag in samples
–
Position error on each line, before correction
–m

Notes and sources

The layback shift moves each reading from the antenna’s time to where the sensor was: with 80 m of layback at 4.5 kn the sensor passes a point 34.6 s after the antenna, 346 samples at 10 Hz. A timing lag shows up on lines run in opposite directions: the same target is pushed forward along each line, so on the two lines it appears twice, dsep apart. Half the split divided by the speed is the lag: 0.9 m at 2.315 m/s means 0.19 s.

Sources: 3H Consulting: Marine Magnetometer Processing

3.10

Diurnal correction

#

Removes the time-varying external field, measured at a base station or taken from an observatory, from the survey readings.

Tcorr(t) = Tobs(t) − [B(t) − Bref]

Examples
nT
nT
nT
Tcorr Corrected reading–nT
Change at the base station, B − Bref
–nT
Correction applied
–nT

Notes and sources

Diurnal changes reach 100 nT or more, and magnetic storms several hundred; Breiner advises against collecting data meant for correction during a storm. Use a base station near the site, or an observatory, on the same time base as the survey; 3H Consulting also describes tie-line levelling. Example: the base reads 49 856.5 nT against a 49 850.0 nT reference, so 6.5 nT comes off: 49 601.2 becomes 49 594.7 nT.

Sources: Breiner, Applications Manual for Portable Magnetometers, 3H Consulting: Marine Magnetometer Processing

Planning the next survey?

Tell me the site, the data and the dates. I’ll tell you honestly whether I’m the right person for it.

Get in touch